遠瞻分享丨機房防雷小知識
發布時間:2020-03-06 瀏覽量:1239
數字化(hua)、信息化(hua)時代的來臨,微電(dian)子(zi)網(wang)絡設備的普遍應用(yong),使得防雷的問(wen)題顯得越來越重(zhong)要。由(you)于(yu)微電(dian)子(zi)設備具(ju)有高密度、高速度、低(di)電(dian)壓、和低(di)功耗等(deng)特性,這(zhe)就(jiu)使其對各種諸如(ru)雷電(dian)過電(dian)壓、電(dian)力系統(tong)操作過電(dian)壓、靜電(dian)(dian)放電(dian)(dian)、電磁(ci)輻(fu)射等電(dian)磁(ci)干(gan)擾非常敏感。如果防護措施不(bu)力,隨(sui)時隨(sui)地(di)可能遭受重(zhong)大損失(shi)。值(zhi)得我們關注(zhu)的是(shi)雷電(dian)不(bu)僅(jin)僅(jin)破壞系統設備,更為重(zhong)要的是(shi)使系統的通訊中斷、工(gong)作停頓(dun)、其間接(jie)損失(shi)無法估量。
一般(ban)來說,網絡集成系統是(shi)由主服(fu)務器及中心交換機(ji)和各(ge)分交換機(ji)以(yi)及路由器、服(fu)務器、相當數(shu)量的終端構成。位于主機(ji)房內的中心(xin)交換機(ji)通過廣域網(wang)路由器與外界聯系(xi),通過光纖(xian)與各(ge)分交換機連(lian)接,分交換機通過集線器與各(ge)用戶終(zhong)端相連(lian)。
電(dian)(dian)力線是雷(lei)電(dian)(dian)侵入(ru)的重要渠道(dao),雷(lei)電(dian)(dian)襲擊(ji)機房供電(dian)(dian)的電(dian)(dian)力線主要有三種方(fang)式(shi),即:遠點(dian)雷(lei)擊(ji)、近(jin)點(dian)雷(lei)擊(ji)和錯(cuo)相位雷(lei)擊(ji)。
1.近(jin)點(dian)雷(lei)擊(ji):雷(lei)電(dian)(dian)近(jin)點(dian)襲(xi)擊(ji)電(dian)(dian)力線(xian)(xian),實際上是雷(lei)電(dian)(dian)襲(xi)擊(ji)用電(dian)(dian)設(she)備所在的(de)建筑物的(de)避(bi)雷(lei)針,從而引(yin)起雷(lei)電(dian)(dian)電(dian)(dian)磁脈(mo)沖的(de)保護(hu)問題。避(bi)雷(lei)針引(yin)下(xia)(xia)線(xian)(xian)由于電(dian)(dian)感作用,zui大只(zhi)能(neng)將(jiang)50%的(de)電(dian)(dian)流引(yin)入大地(di)(di)。30米以(yi)上的(de)樓體引(yin)下(xia)(xia)線(xian)(xian)只(zhi)能(neng)引(yin)下(xia)(xia)較少電(dian)(dian)流,其(qi)余則通(tong)(tong)過地(di)(di)面有連接的(de)水(shui)管,電(dian)(dian)力屏(ping)蔽槽等聯合引(yin)雷(lei),其(qi)中(zhong)有25%擊(ji)穿UPS輸出負(fu)載的(de)電(dian)(dian)源線(xian)(xian)及(ji)局域(yu)網(wang)線(xian)(xian)等設(she)備后,通(tong)(tong)過邏(luo)輯地(di)(di)線(xian)(xian)入地(di)(di)。其(qi)中(zhong)包(bao)括UPS的(de)輸入、輸出的(de)火線(xian)(xian)對地(di)(di)線(xian)(xian)端。為(wei)此,必須對UPS及(ji)重要(yao)用電(dian)(dian)設(she)備如(ru)小型(xing)機、服務器等設(she)備進行等電(dian)(dian)位保護(hu),對網(wang)絡端口進行保護(hu),堵死一切雷(lei)電(dian)(dian)導入的(de)端口,才能(neng)有效的(de)保護(hu)設(she)備免受雷(lei)電(dian)(dian)襲(xi)擊(ji)。
2.遠(yuan)點(dian)雷擊:即根據磁(ci)電(dian)(dian)(dian)(dian)轉換原理電(dian)(dian)(dian)(dian)力(li)供給(gei)線(xian)路(lu)上輸送50赫茲的(de)(de)交變電(dian)(dian)(dian)(dian)流(liu),線(xian)路(lu)隨(sui)之產生交變的(de)(de)磁(ci)場,雷擊擊穿大(da)氣(qi)時產生高壓電(dian)(dian)(dian)(dian)場,雷擊高壓電(dian)(dian)(dian)(dian)場通(tong)過靜電(dian)(dian)(dian)(dian)吸收原理,向大(da)地方(fang)向運動(dong)。在下雨天氣(qi),空氣(qi)濕(shi)度增大(da),此時雷電(dian)(dian)(dian)(dian)較易擊穿空氣(qi)通(tong)過電(dian)(dian)(dian)(dian)力(li)線(xian)的(de)(de)保護地入(ru)地,從而因較高的(de)(de)電(dian)(dian)(dian)(dian)壓損毀用電(dian)(dian)(dian)(dian)設備。為此,防雷必須首(shou)先考慮遠(yuan)點(dian)雷擊。
3.錯(cuo)相(xiang)位(wei)雷(lei)擊:一個高能量(liang)的(de)(de)雷(lei)擊在一條火線(xian)上,一個低能量(liang)的(de)(de)雷(lei)擊在另一條火線(xian)上,線(xian)線(xian)之間產(chan)生一個壓(ya)差,從而侵入設備(bei)造成雷(lei)電的(de)(de)二次(ci)雷(lei)擊稱錯(cuo)位(wei)雷(lei)擊,為此,對于UPS的(de)(de)輸入和輸出端也應安(an)裝保護。
小(xiao)結:雷(lei)擊可以產生不(bu)同的(de)(de)破(po)壞形式,國際電(dian)工委(wei)員會(hui)已將雷(lei)電(dian)災害(hai)稱為(wei)(wei)“電(dian)子時代的(de)(de)一大公(gong)害(hai)”,雷(lei)擊、感(gan)應雷(lei)擊、電(dian)源尖(jian)波等(deng)瞬間過(guo)電(dian)壓已成為(wei)(wei)破(po)壞電(dian)子設備(bei)的(de)(de)罪魁禍首。機(ji)房防雷(lei),是保障設備(bei)安(an)全(quan)(quan)、操作(zuo)人員(yuan)安(an)全(quan)(quan)和(he)設備(bei)正(zheng)常運行的必要(yao)措施。