遠瞻分享丨機房防雷小知識
發布時間:2020-03-06 瀏覽量:1239
數字化(hua)、信息化(hua)時代的(de)來臨,微電(dian)(dian)子(zi)網絡設備(bei)的(de)普遍應用,使得(de)防雷的(de)問(wen)題顯得(de)越來越重要。由于微電(dian)(dian)子(zi)設備(bei)具(ju)有高密度、高速度、低電(dian)(dian)壓(ya)(ya)、和低功(gong)耗等特性,這就(jiu)使其(qi)對(dui)各種諸如雷電(dian)(dian)過電(dian)(dian)壓(ya)(ya)、電(dian)(dian)力系統操作過電(dian)(dian)壓(ya)(ya)、靜電放電、電磁(ci)輻射(she)等電磁干擾非(fei)常敏感。如果防(fang)護措施不力,隨時(shi)隨地(di)可能遭(zao)受(shou)重(zhong)大損(sun)失(shi)。值得(de)我們(men)關注的(de)是雷電不僅(jin)僅(jin)破(po)壞系(xi)(xi)統設備,更(geng)為重(zhong)要的(de)是使(shi)系(xi)(xi)統的(de)通訊中斷、工(gong)作(zuo)停頓、其(qi)間(jian)接損(sun)失(shi)無法估量。
一(yi)般來說,網絡集成(cheng)系統是由主服務器及中(zhong)心(xin)交(jiao)換(huan)機(ji)和各分交(jiao)換(huan)機(ji)以(yi)及路(lu)由器、服務器(qi)、相當數量的終端構成。位(wei)于主機房內的中心交換(huan)機通過廣域網路(lu)由器(qi)與外界聯系,通過光纖與(yu)各分(fen)交(jiao)換(huan)機連接,分(fen)交(jiao)換(huan)機通過集線器與(yu)各用戶終端(duan)相連。
電(dian)力線(xian)是雷(lei)電(dian)侵入的(de)重要渠道,雷(lei)電(dian)襲擊機房供電(dian)的(de)電(dian)力線(xian)主要有三(san)種方式,即:遠點(dian)雷(lei)擊、近點(dian)雷(lei)擊和錯(cuo)相位雷(lei)擊。
1.近(jin)點雷(lei)(lei)(lei)(lei)擊(ji)(ji):雷(lei)(lei)(lei)(lei)電(dian)(dian)(dian)近(jin)點襲(xi)擊(ji)(ji)電(dian)(dian)(dian)力線(xian)(xian)(xian),實(shi)際上(shang)是雷(lei)(lei)(lei)(lei)電(dian)(dian)(dian)襲(xi)擊(ji)(ji)用(yong)電(dian)(dian)(dian)設(she)備(bei)(bei)所在的(de)(de)建筑物(wu)的(de)(de)避雷(lei)(lei)(lei)(lei)針(zhen),從(cong)而(er)引(yin)起雷(lei)(lei)(lei)(lei)電(dian)(dian)(dian)電(dian)(dian)(dian)磁脈沖的(de)(de)保(bao)護(hu)(hu)問題(ti)。避雷(lei)(lei)(lei)(lei)針(zhen)引(yin)下線(xian)(xian)(xian)由于電(dian)(dian)(dian)感作用(yong),zui大只(zhi)能將50%的(de)(de)電(dian)(dian)(dian)流引(yin)入大地(di)。30米以上(shang)的(de)(de)樓體引(yin)下線(xian)(xian)(xian)只(zhi)能引(yin)下較少電(dian)(dian)(dian)流,其余則通過地(di)面有(you)連接的(de)(de)水(shui)管,電(dian)(dian)(dian)力屏蔽槽等聯(lian)合引(yin)雷(lei)(lei)(lei)(lei),其中(zhong)有(you)25%擊(ji)(ji)穿UPS輸出負(fu)載的(de)(de)電(dian)(dian)(dian)源線(xian)(xian)(xian)及(ji)(ji)局域網(wang)線(xian)(xian)(xian)等設(she)備(bei)(bei)后(hou),通過邏輯(ji)地(di)線(xian)(xian)(xian)入地(di)。其中(zhong)包括UPS的(de)(de)輸入、輸出的(de)(de)火(huo)線(xian)(xian)(xian)對地(di)線(xian)(xian)(xian)端。為此,必須對UPS及(ji)(ji)重要用(yong)電(dian)(dian)(dian)設(she)備(bei)(bei)如小(xiao)型(xing)機、服(fu)務器等設(she)備(bei)(bei)進(jin)行(xing)等電(dian)(dian)(dian)位保(bao)護(hu)(hu),對網(wang)絡端口(kou)進(jin)行(xing)保(bao)護(hu)(hu),堵死一切雷(lei)(lei)(lei)(lei)電(dian)(dian)(dian)導入的(de)(de)端口(kou),才能有(you)效(xiao)的(de)(de)保(bao)護(hu)(hu)設(she)備(bei)(bei)免受雷(lei)(lei)(lei)(lei)電(dian)(dian)(dian)襲(xi)擊(ji)(ji)。
2.遠(yuan)點雷(lei)(lei)擊:即根據磁電(dian)(dian)(dian)轉換原(yuan)理電(dian)(dian)(dian)力(li)供給線(xian)路(lu)(lu)上輸(shu)送50赫(he)茲的交(jiao)(jiao)變(bian)電(dian)(dian)(dian)流,線(xian)路(lu)(lu)隨之(zhi)產(chan)生交(jiao)(jiao)變(bian)的磁場(chang),雷(lei)(lei)擊擊穿大(da)氣(qi)(qi)時(shi)產(chan)生高壓(ya)電(dian)(dian)(dian)場(chang),雷(lei)(lei)擊高壓(ya)電(dian)(dian)(dian)場(chang)通(tong)過靜電(dian)(dian)(dian)吸(xi)收原(yuan)理,向大(da)地方向運(yun)動。在下雨(yu)天氣(qi)(qi),空氣(qi)(qi)濕(shi)度增大(da),此時(shi)雷(lei)(lei)電(dian)(dian)(dian)較(jiao)易擊穿空氣(qi)(qi)通(tong)過電(dian)(dian)(dian)力(li)線(xian)的保護(hu)地入(ru)地,從而因較(jiao)高的電(dian)(dian)(dian)壓(ya)損毀用電(dian)(dian)(dian)設備。為此,防雷(lei)(lei)必須(xu)首先考慮遠(yuan)點雷(lei)(lei)擊。
3.錯相(xiang)位雷(lei)擊:一(yi)個(ge)(ge)高能量(liang)的(de)(de)雷(lei)擊在一(yi)條火線上,一(yi)個(ge)(ge)低能量(liang)的(de)(de)雷(lei)擊在另(ling)一(yi)條火線上,線線之間產生一(yi)個(ge)(ge)壓(ya)差,從而侵入設備造成雷(lei)電的(de)(de)二次(ci)雷(lei)擊稱錯位雷(lei)擊,為此,對于(yu)UPS的(de)(de)輸(shu)入和輸(shu)出端也應安裝保護。
小結(jie):雷(lei)(lei)擊(ji)可(ke)以產生不同的破壞(huai)形式,國際電(dian)(dian)工委(wei)員會已(yi)(yi)將雷(lei)(lei)電(dian)(dian)災(zai)害稱為(wei)(wei)“電(dian)(dian)子時代(dai)的一大公害”,雷(lei)(lei)擊(ji)、感應(ying)雷(lei)(lei)擊(ji)、電(dian)(dian)源(yuan)尖波等瞬間(jian)過電(dian)(dian)壓已(yi)(yi)成為(wei)(wei)破壞(huai)電(dian)(dian)子設備的罪魁禍(huo)首。機房防雷(lei)(lei),是保障設備安(an)全(quan)、操作人員(yuan)安(an)全(quan)和設備正常運行的(de)必要措(cuo)施。